CP-M High Performance Compact Wall-Hung Condensing Boilers

MORE

  • High Efficiency – ETL listed
  • Boiler/System Control Options
  • Flexible Flue Arrangements
  • 6 Models – outputs from 60 to 180Kw

LESS

  • Low Carbon Emissions
  • Fuel running cost savings
  • Lower Installation costs
  • Less Space required

The CP-M boiler works in much the same way as a standard fan-flued boiler does except that it has a larger heat exchanger, made of stainless steel, which absorbs more heat from the burner and the flue gasses. Given the right conditions (Return water cool enough to cool the gasses below 54°C) the flue gasses condense and release latent heat back into the boiler, this would otherwise be wasted. The flue gasses from standard boilers are generally above 300°C, on the CP-M boiler they can be as low as 50°C for the majority of operation, so the potential for fuel savings and lower carbon emissions are obvious.

 

All boilers are less efficient when oversized and output should be carefully matched to demand. The CP-M has a pre-mix, class 5 low NOx, fully modulating burner that will mirror the design requirements of the system and turn down to the exact output needed. This helps to ensure that the boiler is a perfect companion to the heating system.

 

The CP-M has a larger heat exchanger than a standard boiler and therefore it will always be more efficient even when not condensing. Radiators can be oversized to make the boiler condense more often but this is not generally cost effective and they should be sized as for a conventional boiler. The key to maximising the potential of the CP-M is in the effectiveness of the "on board" controls system.

Weather Compensation

 

All CP-M boilers have a built in weather compensation device and a cascade management system.

 

The weather compensator adjusts the demand for heat in response to the outside temperature. This enables the boiler to modulate and run at lower temperatures, allowing the boiler to operate in condensing mode for as long as possible.

 

In order to operate the weather compensation device, an external temperature sensor is required. This is available as an Ancillary Option.

Cascade Management

 

A system load of up to 1304 kW can be shared between up to 8 CP-M boilers. This ensures that the system requirements are matched exactly with the added advantage of optimum efficiency of the burners. It also provides "back-up" protection should one of the units be out of operation for any maintenance purposes. The cascade management can also be controlled externally through an in-built 0-10 VDC connection on the boiler panel.

Controls

 

The CP-M controls can also be interrogated by a laptop computer to give performance data revealing the operation of the boiler from the moment that it is powered up. This gives assurances that the boiler is set to cope with the system requirements and allows any necessary running adjustments to be made in order to further "trim" the controls.

Flue Options

 

CP-M Boilers are built with a concentric spigot as standard. An option for twin pipe (flue & air ducts) is available for long flue runs.

Product Information

 

CPM Product Information

 

PDF Downloads

 

You will need Adobe Acrobat to be able to read these files. If you do not have this program then please click on the Adobe icon to download it.

 

CAD Downloads

 

Model
Download CAD Drawing
View CAD Drawing
CP-M 60
CP-M 80
CP-M 100
CP-M 120
CP-M 150
CP-M 180
 
All of the CP-M Series CAD drawings in one zip file.
n/a

 

For more details about the CAD drawings and how to view them please click here.

 

 

 


Back   Top Of Page